Assessing heat stress in hospital wards using Wet Bulb Globe temperature: A case study in Mediterranean climate

FILIPPIDOU, KYVELI, Giridharan, R. (2020) Assessing heat stress in hospital wards using Wet Bulb Globe temperature: A case study in Mediterranean climate. In: 35th PLEA CONFERENCE: PLANNING POST CARBON CITIES 1-3 September 2020 A Coruña, Spain, 1-3 September 2020, Coruña, Spain. (KAR id:91407)

PDF Author's Accepted Manuscript
Language: English
Download this file
(PDF/764kB)
[thumbnail of 1176-Kyveli_Filippidou-final.pdf]
Preview
Request a format suitable for use with assistive technology e.g. a screenreader
Microsoft Word Author's Accepted Manuscript
Language: English

Restricted to Repository staff only
Contact us about this Publication
[thumbnail of 1176-Kyveli_Filippidou-final.doc]
Official URL:
https://doi.org/10.17979/spudc.9788497497947 ​

Abstract

In the context of climate change, there is increasing concern about the likelihood of overheating in hospitals. The aim of this paper is to investigate the heat stress exposure through the Wet Bulb Globe Temperature (WBGT) heat index in four different rooms of the 1st Internal Medicine Department of the American Hellenic Educational Progressive Association (AHEPA) hospital located in Thessaloniki, Greece. In hospital environments patients usually have restricted adaptive opportunity. Thus, the need for an indoor heat-safety metric is imperative. This study proposes thresholds of 24oC and 26oC to assess critical ward spaces as these are the initial warning points for nighttime thermal discomfort of healthy individuals in ‘normal’ environments. In this context, the internal temperatures measured in the patients’ rooms were plotted against the indoor WBGT thresholds for a low wind velocity of 0.1m/sec. Between the 13th and the 22th of June 2017 the most extreme temperatures were recorded in room 3, while the mildest conditions occurred in room 1. WBGT ranged between 19⁰C and 25.46⁰C. The recorded WBGT in three rooms exceeded the threshold of 24oC for approximately one-third of the time, while in one room it was marginally below the proposed threshold.

Item Type: Conference or workshop item (Proceeding)
Uncontrolled keywords: Heat stress, Wet bulb globe temperature, monitoring, hospital
Subjects: T Technology
T Technology > TH Building construction
Divisions: Divisions > Division of Arts and Humanities > Kent School of Architecture and Planning
Depositing User: Giridharan Renganathan
Date Deposited: 08 Nov 2021 10:42 UTC
Last Modified: 09 Nov 2021 16:30 UTC
Resource URI: https://kar.kent.ac.uk/id/eprint/91407 (The current URI for this page, for reference purposes)

University of Kent Author Information

  • Depositors only (login required):

Total unique views for this document in KAR since July 2020. For more details click on the image.