The effect of signal acquisition and processing choices on ApEn values: Towards a “gold standard” for distinguishing effort levels from isometric force records

Forrest, Sarah M., Challis, John H., Winter, Samantha L. (2014) The effect of signal acquisition and processing choices on ApEn values: Towards a “gold standard” for distinguishing effort levels from isometric force records. Medical Engineering & Physics, 36 (6). pp. 676-683. ISSN 1350-4533. (doi:10.1016/j.medengphy.2014.02.017) (KAR id:47690)

Abstract

Approximate Entropy (ApEn) is frequently used to identify changes in the complexity of isometric force records with ageing and disease. Different signal acquisition and processing parameters have been used, making comparison or confirmation of results difficult. This study determined the effect of sampling and parameter choices by examining changes in ApEn values across a range of submaximal isometric contractions of the First Dorsal Interosseus. Reducing the sample rate by decimation changed both the value and pattern of ApEn values dramatically. The pattern of ApEn values across the range of effort levels was not sensitive to the filter cut-off frequency, or the criterion used to extract the section of data for analysis. The complexity increased with increasing effort levels using a fixed ‘r’ value (which accounts for measurement noise) but decreased with increasing effort level when ‘r’ was set to 0.1 of the standard deviation of force. It is recommended isometric force records are sampled at frequencies >200 Hz, template length (‘m’) is set to 2, and 'r' set to measurement system noise or 0.1 SD depending on physiological process to be distinguished. It is demonstrated that changes in ApEn across effort levels are related to changes in force gradation strategy.

Item Type: Article
DOI/Identification number: 10.1016/j.medengphy.2014.02.017
Additional information: Full text upload compliant with journal regulations
Uncontrolled keywords: complexity, isometric muscle force, first dorsal interosseus
Subjects: Q Science > QP Physiology (Living systems)
Divisions: Divisions > Division of Natural Sciences > Sport and Exercise Sciences
Depositing User: Samantha Winter
Date Deposited: 30 Nov 2015 17:29 UTC
Last Modified: 05 Nov 2024 10:31 UTC
Resource URI: https://kar.kent.ac.uk/id/eprint/47690 (The current URI for this page, for reference purposes)

University of Kent Author Information

  • Depositors only (login required):

Total unique views for this document in KAR since July 2020. For more details click on the image.