Fabrication and evaluation of a freestanding pyroelectric detector made from single-crystal LiNbO3 film

Lehman, John H., Radojevic, Antonije M., Osgood, Richard M., Levy, Miguel, Pannell, Christopher N. (2000) Fabrication and evaluation of a freestanding pyroelectric detector made from single-crystal LiNbO3 film. Optics Letters, 25 (22). pp. 1657-1659. ISSN 0146-9592. (doi:10.1364/OL.25.001657) (The full text of this publication is not currently available from this repository. You may be able to access a copy if URLs are provided) (KAR id:16310)

The full text of this publication is not currently available from this repository. You may be able to access a copy if URLs are provided.
Official URL:
http://dx.doi.org/10.1364/OL.25.001657

Abstract

We have packaged a rectangular 3 mm×4 mm, 10‐µm-thick Z-cut lithium niobate (LiNbO3) film produced by crystal ion slicing (CIS) and evaluated its performance as a pyroelectric optical detector. We justify the difficulty of preparing the film by showing that the freestanding detector has much greater sensitivity than the same detector bonded to a substrate. We compare the sensitivity of three CIS-film detectors with that of a detector based on a 230‐µm-thick LiNbO3 plate and describe the detectors’ spatial uniformity and noise-equivalent power.

Item Type: Article
DOI/Identification number: 10.1364/OL.25.001657
Subjects: Q Science
Divisions: Divisions > Division of Natural Sciences > Physics and Astronomy
Depositing User: O.O. Odanye
Date Deposited: 02 Apr 2009 12:13 UTC
Last Modified: 05 Nov 2024 09:51 UTC
Resource URI: https://kar.kent.ac.uk/id/eprint/16310 (The current URI for this page, for reference purposes)

University of Kent Author Information

Pannell, Christopher N..

Creator's ORCID:
CReDIT Contributor Roles:
  • Depositors only (login required):

Total unique views for this document in KAR since July 2020. For more details click on the image.