Simmons, Owen, De Wilde, Philippe, Podoleanu, Adrian (2026) Image-driven OCT calibration from a single B-scan. Biomedical Optics Express, 17 (9). ISSN 2156-7085. (doi:10.1364/BOE.608117) (KAR id:115912)
|
PDF
Publisher pdf
Language: English
This work is licensed under a Creative Commons Attribution 4.0 International License.
|
|
|
Download this file (PDF/6MB) |
Preview |
| Request a format suitable for use with assistive technology e.g. a screenreader | |
|
PDF
Author's Accepted Manuscript
Language: English Restricted to Repository staff only
This work is licensed under a Creative Commons Attribution 4.0 International License.
|
|
|
Contact us about this publication
|
|
| Official URL: https://doi.org/10.1364/BOE.608117 |
|
Abstract
Optical coherence tomography (OCT) requires accurate calibration of wavenumber sampling and dispersion compensation to achieve optimal axial resolution. Conventional calibration methods rely on dedicated mirror measurements acquired at multiple optical path differences, requiring dedicated acquisitions, careful alignment, and additional acquisition time. We present a physics-informed optimisation framework that recovers OCT calibration directly from a single routine B-scan. Within the complex leader-follower reconstruction framework, the method jointly estimates wavenumber remapping and dispersion compensation functions by optimising image quality in reconstructed OCT data. Experiments on a swept-source OCT system demonstrate that the recovered calibration functions produce image quality comparable to conventional mirror-based calibration while requiring only a single acquired image and 30–60 seconds of optimisation. Samples containing depth-distributed structure recover calibration functions closely matching the underlying system calibration, whereas structurally limited samples produce image-specific effective calibration within the observed depth range. These results demonstrate the feasibility of rapid software-defined OCT calibration directly from imaging data, reducing dependence on dedicated calibration measurements, and simplifying OCT system operation.
| Item Type: | Article |
|---|---|
| DOI/Identification number: | 10.1364/BOE.608117 |
| Additional information: | For the purpose of open access, the author(s) has applied a Creative Commons Attribution (CC BY) licence to any Author Accepted Manuscript version arising. |
| Subjects: | Q Science > QC Physics > QC355 Optics |
| Institutional Unit: |
Schools > School of Engineering, Mathematics and Physics > Physics and Astronomy Schools > School of Natural Sciences > Biosciences |
| Former Institutional Unit: |
There are no former institutional units.
|
| Funders: |
Medical Research Council (https://ror.org/03x94j517)
National Institute for Health Research (https://ror.org/0187kwz08) Engineering and Physical Sciences Research Council (https://ror.org/0439y7842) |
| Depositing User: | Owen Simmons |
| Date Deposited: | 18 Aug 2026 08:08 UTC |
| Last Modified: | 11 Sep 2026 15:45 UTC |
| Resource URI: | https://kar.kent.ac.uk/id/eprint/115912 (The current URI for this page, for reference purposes) |
- Link to SensusAccess
- Export to:
- RefWorks
- EPrints3 XML
- BibTeX
- CSV
- Depositors only (login required):

https://orcid.org/0009-0004-7813-6503
Altmetric
Altmetric