Székely, Orsolya, Holmes, Nicholas P., Ashton, Jennifer, Breuer, Friederike, Chen, Hsin-Yuan, Di Chiaro, Nunzia Valentina, Duport, Arnaud, Frangou, Polytimi, Gwynne, Louisa, Hassan, Umair, and others. (2026) Development and Validation of the Transcranial Magnetic Stimulation Reporting Assessment Tool (TMS-RAT). Brain Stimulation, 19 (5). Article Number 103155. ISSN 1935-861X. (doi:10.1016/j.brs.2026.103155) (KAR id:115705)
|
PDF
Publisher pdf
Language: English
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
|
|
|
Download this file (PDF/3MB) |
Preview |
| Request a format suitable for use with assistive technology e.g. a screenreader | |
|
PDF
Author's Accepted Manuscript
Language: English Restricted to Repository staff only
This work is licensed under a Creative Commons Attribution 4.0 International License.
|
|
|
|
|
| Official URL: https://doi.org/10.1016/j.brs.2026.103155 |
|
Abstract
Background: A standardised tool for comprehensive reporting can improve transparency, support consistent documentation, and enable comparison across transcranial magnetic stimulation (TMS) studies. The most used reporting checklist lacks clear definitions of full reporting and was not initially evaluated for usability or inter-rater reliability. A scoping review of studies using this checklist shows that its items are reported only 50% of the time, suggesting that method descriptions are often incomplete.
Methods: We developed the TMS Reporting Assessment Tool (TMS-RAT), a comprehensive reporting framework that provides clear definitions and examples for its items, covering a wide range of TMS protocols. We tested the usability and reliability of the TMS-RAT by rating all studies published between 1991 and 2025 using afferent conditioning (n = 333), a protocol encompassing many reporting categories identified during tool development. Seventeen independent raters contributed across three development phases, a validation phase, and a retest phase, with naïve raters introduced in each phase. Iterative refinements of the tool were informed by inter-rater reliability, qualitative rater feedback, and consultation with external TMS experts.
Results: We present two versions of the tool: the 72-item TMS-RAT v1.0, designed to guide comprehensive reporting, and the TMS-RAT v1.1, a subset of 50 items with the highest inter-rater (overall AC1 = 0.78, range = [0.60–0.99]) and test-retest reliability (overall AC1 = 0.82, range = [0.65–1.0]), intended for retrospective evaluation of reporting in systematic reviews, meta-analyses.
Conclusion: The TMS-RAT is a comprehensive, reliable tool that seeks to improve transparency and reproducibility in TMS research.
| Item Type: | Article |
|---|---|
| DOI/Identification number: | 10.1016/j.brs.2026.103155 |
| Uncontrolled keywords: | Transcranial magnetic stimulation, Reporting assessment, Reporting guidelines, Reproducibility, Inter-rater reliability, Test-retest reliability |
| Subjects: | R Medicine |
| Institutional Unit: | Schools > School of Psychology |
| Former Institutional Unit: |
There are no former institutional units.
|
| Funders: | Medical Research Council (https://ror.org/03x94j517) |
| Depositing User: | Luigi Tame |
| Date Deposited: | 02 Jul 2026 10:10 UTC |
| Last Modified: | 13 Aug 2026 09:04 UTC |
| Resource URI: | https://kar.kent.ac.uk/id/eprint/115705 (The current URI for this page, for reference purposes) |
- Link to SensusAccess
- Export to:
- RefWorks
- EPrints3 XML
- BibTeX
- CSV
- Depositors only (login required):

https://orcid.org/0000-0002-9172-2281
Altmetric
Altmetric