Breathing pattern disorders distinguished from healthy breathing patterns using optoelectronic plethysmography

Smyth, Carol M.E., Winter, Samantha L., Dickinson, John W. (2022) Breathing pattern disorders distinguished from healthy breathing patterns using optoelectronic plethysmography. Translational Sports Medicine, . Article Number 2816781. E-ISSN 2573-8488. (doi:10.1155/2022/2816781) (KAR id:98682)

PDF Publisher pdf
Language: English


Download (1MB) Preview
[thumbnail of Smyth et al 2022 BPD vs. healthy breathing patterns.pdf]
Preview
This file may not be suitable for users of assistive technology.
Request an accessible format
Official URL:
https://www.hindawi.com/journals/tsmed/2022/281678...

Abstract

Tere is no gold standard diagnostic method for breathing pattern disorders (BPD) which is commonly diagnosed through the exclusion of other pathologies. Optoelectronic plethysmography (OEP) is a 3D motion capture technique that provides a comprehensive noninvasive assessment of chest wall during rest and exercise. Te purpose of this study was to determine if OEP can distinguish between active individuals classifed with and without BPD at rest and during exercise. Forty-seven individuals with a healthy breathing pattern (HBP) and twenty-six individuals with a BPD performed a submaximal exercise challenge. OEP measured the movement of the chest wall through the calculation of timing, percentage contribution, and phase angle breathing pattern variables. A mixed model repeated measures ANOVA analysed the OEP variables between the groups classified as HBP and BPD at rest, during exercise, and after recovery. At rest, regional contribution variables including ribcage percentage contribution (HBP: 71% and BPD: 69%), abdominal ribcage contribution (HBP: 13% and BPD: 11%), abdomen percentage contribution (HBP: 29% and BPD: 31%), and ribcage and abdomen volume index (HPB: 2.5 and BPD: 2.2) were significantly (p < 0.05) different between groups. During exercise, BPD displayed significantly (p < 0.05) more asynchrony between various thoracic compartments including the ribcage and abdomen phase angle (HBP: −1.9 and BPD: −2.7), pulmonary ribcage and abdomen phase angle (HBP: −0.5 and BPD, 0.5), abdominal ribcage and shoulders phase angle (HBP: −0.3 and BPD: 0.6), and pulmonary ribcage and shoulders phase angle (HBP: 0.2 and BPD: 0.6). Additionally, the novel variables inhale deviation (HBP: 8.8% and BPD: 19.7%) and exhale deviation (HBP: −10.9% and BPD: −17.6%) were also significantly (p < 0.05) different between the groups during high intensity exercise. Regional contribution and phase angles measured via OEP can distinguish BPD from HBP at rest and during exercise. Characteristics of BPD include asynchronous and thoracic dominant breathing patterns that could form part of future objective criteria for the diagnosis of BPD.

Item Type: Article
DOI/Identification number: 10.1155/2022/2816781
Subjects: R Medicine > RC Internal medicine > RC1200 Sports medicine
Divisions: Divisions > Division of Natural Sciences > Sport and Exercise Sciences
Depositing User: John Dickinson
Date Deposited: 05 Dec 2022 09:54 UTC
Last Modified: 14 Dec 2022 11:30 UTC
Resource URI: https://kar.kent.ac.uk/id/eprint/98682 (The current URI for this page, for reference purposes)